The PIR-2C pulse isolation relay is designed to provide two sets of isolated "dry", mercury-wetted form "C" (K, Y & Z) contacts from a single form "A" input. Typical applications involve pulse isolation and Form A to Form C pulse conversion. Other applications include interfaces between utility metering devices and customer- owned energy control systems, demand recorder applications, and supervisory control systems (SCADA) interfaces. A bright yellow LED lamp indicates the system's status at all times thus allowing a rapid check of the system's performance without requiring any additional test equipment.
| Power Input | 90 to 325 VAC. Burden: 10 MA. at 120 VAC |
| Output | Two sets of "dry" Form "C" contacts (K, Y & Z). The contacts are mercury-wetted "no bounce" relays rated at 500 VDC or 350 VAC 2 Amps. break, 5 amps carry. The maximum rating of the contacts is 100 VA. Factory fused at 1/2 amp. (3AG) |
| Contact Resistance | 50 milliohms maximum, 12 to 14 typical |
| Insulation Resistance | 50 megohms typical |
| Operate and Release Time | 1 to 2 milliseconds typical |
| Mounting | Within 30 degrees of vertical |
| Size | 3.27 inches wide, 5.65 inches high, 1.50 inches deep |
| Weight | 13 ounces |
| Temperature Range | -38° C to +70° C, -36.4° F to +158° F |
| Humidity | 0 to 98% non-condensing |
| Input Voltages | 125 VDC input using the DCS-1 Power Supply. Contact factory for other input voltages. |